Purpose
Use this procedure when a customer wants to view, adjust, or understand Threshold Settings on an Ecobee thermostat.
Customer Symptoms
Customer wants to:
- Adjust heating thresholds
- Adjust cooling thresholds
- Enable Auto Heat/Cool
- Improve HVAC efficiency
- Control staging settings
- Configure heat pump behavior
- Adjust compressor settings
- Modify temperature differentials
- Fine-tune thermostat operation
Important Warning
Threshold Settings directly affect HVAC operation.
If the customer is unfamiliar with their heating and cooling equipment, recommend consulting an HVAC professional or Ecobee Support before making changes.
Access Threshold Settings
Ecobee Smart Thermostats
- Open Main Menu.
- Select Settings.
- Select Installation Settings.
- Select Thresholds.
Smart Thermostat Lite and Essential
- Open Main Menu.
- Select Settings.
- Select Installation Settings.
- Select Thresholds.
Automatic vs Manual Staging
Automatic Staging (Recommended)
By default, Ecobee uses Automatic Staging.
Benefits include:
- Automatic heating control
- Automatic cooling control
- Smart equipment staging
- Optimized fan operation
- Energy efficiency management
Manual Staging
Manual Staging allows advanced control over:
- Temperature differentials
- Runtime settings
- Heat stages
- Cooling stages
- Auxiliary heat operation
Heat Pump Systems
If the thermostat controls a heat pump with auxiliary heat:
Aux Savings Optimization
Customers can prioritize:
- Maximum Savings
- Balanced Operation
- Maximum Comfort
For more detailed control, switch staging to Manual.
Common Threshold Settings
Auto Heat/Cool
Allows the thermostat to automatically switch between heating and cooling as needed.
Heat/Cool Minimum Delta
Controls the minimum temperature separation between:
- Heating setpoint
- Cooling setpoint
Heat Dissipation Time
Keeps the fan running briefly after heating stops to circulate remaining warm air.
Cool Dissipation Time
Keeps the fan running briefly after cooling stops to circulate remaining cool air.
Heat Differential Temperature
Determines how far the temperature must drop before heating starts.
Cool Differential Temperature
Determines how far the temperature must rise before cooling starts.
Heat Minimum On Time
Controls the minimum furnace runtime during a heating cycle.
AC Overcool Max
Allows cooling to continue beyond the setpoint to help reduce humidity.
Temperature Correction
Adjusts the thermostat temperature reading.
Range:
- Up to +10°F
- Up to -10°F
Only use if the thermostat is consistently reading too high or too low.
Humidity Correction
Adjusts the thermostat humidity reading.
Only use if humidity readings are consistently inaccurate.
Thermal Protect
Ignores sensors that appear to be reporting inaccurate temperatures.
Compressor Settings
Compressor Minimum Cycle Off Time
Prevents short cycling by requiring a minimum off period.
Compressor Minimum On Time
Sets the minimum compressor runtime.
Compressor Minimum Outdoor Temperature
Determines the lowest outdoor temperature at which the compressor can operate.
Compressor Stage 2 Temperature Delta
Determines when second-stage cooling activates.
Compressor Reverse Staging
Returns the system to first-stage cooling as the setpoint is approached.
Compressor Stage 1 Maximum Runtime
Limits how long first-stage cooling runs before advancing stages.
Heating Stage Settings
Heat Reverse Staging
Returns heating equipment to first-stage operation near the target temperature.
Heat Stage 2 Temperature Delta
Determines when second-stage heating activates.
Heat Stage 1 Maximum Runtime
Limits first-stage heating runtime before advancing.
Auxiliary Heat Settings
Auxiliary Heat Maximum Outdoor Temperature
Prevents auxiliary heat from operating above a specified outdoor temperature.
Auxiliary Heat Minimum On Time
Sets the minimum runtime for auxiliary heat.
Compressor to Auxiliary Temperature Delta
Determines how far the temperature can drift before auxiliary heat engages.
Compressor to Auxiliary Runtime
Determines how long the heat pump runs before switching to auxiliary heat.
Auxiliary Stage 2 Temperature Delta
Determines when second-stage auxiliary heat activates.
Auxiliary Reverse Staging
Disengages auxiliary heat near the end of a heating cycle and returns operation to the heat pump.
Auxiliary Stage 1 Maximum Runtime
Limits first-stage auxiliary heat runtime before second-stage operation begins.
Energy Saving Behavior
During:
- Away Comfort Settings
- Custom Comfort Settings marked "Someone is usually Away"
Ecobee automatically adds:
- 1°F differential
- 0.6°C differential
before starting heating or cooling to improve energy efficiency.
Troubleshooting
System Cycles Too Frequently
Review:
- Heat Differential Temperature
- Cool Differential Temperature
- Minimum On Time settings
Home Feels Too Warm or Too Cool
Review:
- Temperature Correction
- Heat/Cool Delta
- Comfort Settings
Heat Pump Uses Auxiliary Heat Too Often
Review:
- Aux Savings Optimization
- Compressor to Aux Delta
- Compressor to Aux Runtime
Expected Outcome
Threshold Settings are properly configured to balance comfort, HVAC performance, equipment protection, and energy efficiency based on the customer's HVAC system and preferences.